1981  Tolentino, Refojo en Schepens, 'A hydrophilic acrylate implant for scleral buckling: technique and clinical experience' (Retina 1981; 1(4):281-6)     Memorie van grieven, prod. 2
1985  Tolentino, Roldan, Nassif en Refojo, 'Hydrogel Implant for Scleral Buckling', Long-term Observations (Retina 5:38-41, 1985)    Memorie van grieven, prod. 3
1991  Schepens en Acosta, 'Scleral implants: An historical perspective' (Surv Ophthalmol. 1991 May-Jun;35(6):447-53)   Memorie van grieven, prod. 4
1992  Marin, Tolentino, Refojo en Schepens, ‘Long-term Complications of the MAl Hydrogel Intrascleral Buckling Implant’, (Arch Ophthalmol-Vol 110, January 1992)    Dagvaarding, prod. 5
1997  Hwang ea, 'Hydrogel Exoplant Fragmentation 10 Years After Scleral Buckling Surgery', (Arch Ophthalmol Vol 115. Sep 1997 1205)   Dagvaarding, prod.7
1999  Anne-Catherine Gribomont, "Détérioration progressive des explants epliscleraux de type Miragel" BSO 1999   Pleitnota 5-10-2012, prod. 16 
  Roldán-Pallarés ea, Long term complications of silicone and hydrogel explants in retinal reattachment surgery, Arch Ophthalmoll999;117:197-201   Dagvaarding, prod 8
2000  F. D'Hermies e.a.: "Fragmentation des indentations en hydrogel" JFO nr 2. 2000   Pleitnota 5-10-2012, prod. 18
2001  Lane ea, lmaging of Hydrogel Episcleral Buckle Fragmentation as a Late Complication after Retina) Reattachment Surgery, AJNR Am J Neuroradio/ 2001;22:1199-1202   Dagvaarding, prod. 4
2002 Braunstein ea, Complications of Miragel: Pseudotumor, Arch Ophthalmol 2002;120:228-229    Dagvaarding, prod. 9
  Taku Kawano ea, Case Reports: Extrusion and Fragmentation of Hydrogel Exoplant 11 Years After Scleral Buckling Surgery, Ophthalmic Surgery, Lasers and lmaging Vol. 33 No.3 May/June 2002    Dagvaarding, prod. 10
  Le Rouic e.a.: "Ablation des indentations épisclérales en Miragel, Ėtude clinique rétrospective" JFO 2002 p.1002    Pleitnota 5-10-2012, prod. 17
2003 Oshitari ea, Long-term complications ofhydrogel buckles, Retina 2003;23:257-61   Dagvaarding, prod. 11
  Le Rouic ea, Late swelling and removal of rniragel buckles: a comparison with silicone indentations. Retina 2003;23:641-6   Dagvaarding, prod. 12
  Li ea, Miragel explant fragmentation 10 years after sc1eral buckling surgery, Eye (2003) 17, 248-250    Dagvaarding, prod. 13
  Kokame ea, 'Successful management of intruded hydrogel buckle with buckle removal, scleral patch graft, and vitrectomy', Retina 2003, nr. 4, p. 536-538    Memorie van grieven, prod. 12
2004 Keamey ea, Complications ofhydrogel explants used in scleral buckling surgery, Am J Ophthalmol 2004;137:96-100    Dagvaarding, prod. 6
  Metz ea, Late-onset progressive strabismus associated with a hydrogel seleral buckle, J AAPOS 2004;8:72-3    Dagvaarding, prod. 14
  Chung ea, Diplopia and periorbital mass associated with Mirage! buckling explant, Korean J Ophthalmol. 2004 Jun; 18(1):47-51    Dagvaarding, prod. 15
  Mazzoli ea, Use ofself-expanding, hydrophilic osmotic expanders (hydrogel) in the reconstruction of congenital clinical anophthalmos, Current Opinion in Ophthalmology. 15(5):426-431, October 2004    Dagvaarding, prod. 16
2005 Shields ea, Expanding MIRAgel Scleral Buckle Simulating an Orbital Tumor in Four Cases, Ophthal Plast Reconstructive Surg.;2005,Jan; 21(1),32-34    Dagvaarding,  prod. 17
  Ingrid Kreissig (Ed.), Primary Retinal Detachment, Springer 2005     Memorie van grieven prod. 5
  Çekic ea, Removal of the intruding Miragel's Scleraal Buckle by Pars Plena Ultrasonic Fragmentation, Am J Ophthalmol 2005; 139:209-210    Conclusie na deskundigenbericht,  prod. 14
  Bhagat e.a.: Hydrated scleral buckle: a late complication of MA! explants", BJO 2005: p. 89    Pleitnota 5-10-2012, prod. 19
2007 Roldan-Pallares ea, Hydrolytic Degradation and Long-term Observations, Arch Ophthalmol 2007; Vol. 125 NoA    Dagvaarding, prod. 18
2008 Nuzzi ea, Buckle removal in retinal detachment surgery, Acta Biomed 2008,79: 128-132    Akte 19-5-2010, prod. 1
2009 Satu Länsman, Evaluation ofbioabsorbable poly-1/d-lactide implant for scleral buckling, 2009, blz. 39-40    Memorie van grieven, prod. 6
2010 Baino, The Use of Polymers in the Treatment of Retina) Detachment: Current Trends and Future Perspectives, Polymers 2010, 2, 286-322   Memorie van grieven, prod. 7
  Baino. Scleral buckling biomaterials and implants for retinal detachment surgery. In: MEDICAL ENGINEERING & PHYSICS, vol. 32, pp. 945-956. - ISSN 1350-4533    Akte 5-9-2016, prod.2
2011 Hasori e.a.: lntravitreal intrusion of an intrascleral MIRAgel buckling implant, JJO 2011 55:310    Pleitnota 5-10-2012, prod. 20
2012 lrena Tsui, MD, Scleral Buckle Removal: lndications and Outcomes, Survey of ophthalmology, 57-3, May-June 2012    Memorie van grieven, prod. 8
  Crama ea, Een man met progressieve diplopie, Ned Tijdschr Geneeskd. 2012;156:A3185   Memorie van grieven, prod. 10
2014 Mears ea Endophthalmitis secondary to globe penetration from hydrogel scleral buckle, Int J Ophthalmol. Vol.7, No.3, Jun.18, 2014    Memorie in verwijzing na cassatie prod. 4
2016 Crama ea, The Removal of Hydrogel Explants, An Analysis of 467 Consecutive Cases, American Academy of Ophthalmology, 2016   Akte 5-9-2016, prod.1
2016 Thompson ea, Editorial, Good Ideas Gone Bad: The MIRAgel Saga   Memorie in verwijzing na cassatie prod. 7
2016 Rubinstein ea,  Globe Loss from Intraocular Invasion of MIRAgel Scleral Buckle Components, Ophthal Plast Reconstr Surg. 2016    Memorie in verwijzing na cassatie prod. 5
2016 Roldan-Pallares ea, ‘MIRAgel: the immunohisto-chemical expression of CD3, CD34, and CD68 in the surrounding capsule', Eye (2016) 30, 1381–1388   Memorie in verwijzing na cassatie prod. 6